Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Penerangan produk
Atribut Produk
Model No.: AMC16
Jenama: Acrel
Tempat Asal: China
Installation: DIN rail 35mm
Measurement: A+B independent 3 phase circuits, 6DI2DO,2 leakage current,1 temp. and humidity.
Power Supply: With DC 24V output power supply for outgoing line module and touch screen
Communication: RS485 Modbus RTU
Membekalkan Keupayaan & Maklumat Tambaha...
Pembungkusan: Penyelesaian Pemantauan Pengedaran Ketepatan IDC akan dibungkus dalam kotak kadbod dengan filem gelembung
Produktiviti: 100000 sets per year
Pengangkutan: Ocean,Land,Air,Express
Tempat asal: China
Sokongan mengenai: 10000pcs/month
Sijil: CE/IEC/UL/MID
Kod HS: 9028301400
Port: Jiang Yin,Shanghai
Jenis bayaran: L/C,T/T
Incoterm: FOB,CFR,CIF,EXW,CPT
Pembungkusan & Penghantaran
Penerangan produk
Penyelesaian Pemantauan Pengagihan Ketepatan IDC
Ia perlu untuk memantau dan memusatkan penggunaan kuasa di pusat data dan data boleh dipaparkan pada HMI, dan dimuat naik ke sistem pemantauan kuasa dan persekitaran oleh Rs485 pada skrin sentuh dan menyedari pemantauan masa nyata sistem pengedaran kuasa keseluruhan. Pada masa yang sama, ia dapat merealisasikan analisis kecekapan tenaga untuk mengurangkan penggunaan tenaga.
Fungsi utama penyelesaian pemantauan pengagihan ketepatan IDC adalah 1. Inkoming garis dan litar garis keluar Modul Pemantauan Bebas 2. Boleh mengukur sehingga 2 litar talian masuk dan sehingga 192 litar talian keluar semasa, voltan, kuasa, tenaga dan kualiti kuasa. 3. Pemantauan dan dipamerkan data oleh HMI dan data dimuat naik ke sistem pemantauan kuasa dan persekitaran melalui Rs485.
Produk yang berkaitan dengan pusat data termasuk: HMI, pusat tenaga data dwi-litar, transformer semasa, sensor semasa kesan Hall, modul pemantauan talian masuk DC, dan modul pemantauan talian keluar DC.
Struktur
|
|
|
|
Monitoring System For Data Center Energy Management | Main Power Supply Module |
|
|
DC Network Solution | AC Network Solution |
|
|
Main Topography Of Precision Distribution System | Main Power Supply&Backup Power Supply |
Fungsi utama
1) Modul Pemantauan Bebas dan Litar Talian Masuk ;
2) Boleh mengukur sehingga 2 litar talian masuk dan sehingga 192 litar talian keluar semasa, voltan, kuasa, tenaga dan kualiti kuasa ;
3) Pemantauan dan dipamerkan data oleh HMI dan data dimuat naik ke sistem pemantauan kuasa dan persekitaran melalui Rs485 ;
4) Untuk sistem voltan tinggi DC 240V atau 336V, modul pemantauan penebat boleh ditambah untuk memantau rintangan penebat tanah bas utama ;
5) Bekalan kuasa DC24V untuk skrin sentuh dan modul pemantauan talian keluar (bekalan kuasa dari output modul utama) ;
6) Komunikasi: Peranti pemantauan oleh Rs485, skrin sentuh oleh Rs485 atau RJ45 ;
7) Sijil: CE.
Antara muka mesin manusia
|
|
|
Setting | Current Amarm |
Main |
Rajah Kabinet
Pemilihan produk
Product Name |
Product Image |
Functions |
AMC16Z-ZA Data Center Monitor Device |
|
● Designed specifically for the power supply management of server in the data center ● A+B independent 2 channels three-phase inlet ● U, I, P, Q, S, PF, kWh, kvarh ● 2nd-63rd Harmonic |
AMC16Z-FAK48 Data Center Monitor Device |
|
● Designed specifically for the power supply management of server in the data center ● A+B independent 24 circuits(48 in total) ● U, I, P, Q, S, PF, kWh, kvarh ● 2nd-31st Harmonic ● kWh Class 0.5 ● DIN 35 mm |
AMC16Z-ZD DC Incoming Line Monitoring Module |
|
● DIN 35mm ● Measurement: A+B independent circuits, 6DI 2DO,1 temp. and humidity. ● With DC 24V output power supply for outgoing line module and touch screen. ● Communication:RS485 modbus RTU |
AMC16Z-FDK24/48 DC Outgoing Line Monitoring Module |
|
● DIN 35mm ● Can measure up to 48 circuits DC outgoing line ● DC24V power supply ● Communication:RS485 modbus RTU |
AMC16Z-ZJY DC Incoming Line Insulation Monitoring Module |
|
● DIN 35mm ● Measure A+B independent DC circuit ground insulation resistance of main bus ● DC24V power supply ● Communication:RS485 modbus RTU |
AMC16Z-FJY DC Outgoing Line Insulation Monitoring Module |
|
● DIN 35mm ● Measure 24 circuits ground insulation resistance of DC outgoing line |
AKH-0.66/W Current Sensor |
|
● Current ratio:100A/50mA
● Common Specification: 100A/50mA |
AHKC-BS DC Outgoing Line Hall Effect Current Sensor |
|
● Current ratio:100A/5V
● Common Specification: 100A/5V |
ATP007kt ATP010kt HMI |
|
● 7 or 10 inch touch screen
● Real-time monitoring and display voltage,current,power,energy,power quality,switch status,wave curve,etc. of the busbar
● Monitoring device alarm,communication and other parameters can be configured on the screen.
● 2 RS485 and 1 Ethernet,and data can uploaded by RS485 or RJ45 |
Gambar di laman web
|
|
|
Produk panas
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Fill in more information so that we can get in touch with you faster
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.